PC9155 Wireless Alarm System
2-1
2 Installation
This chapter describes how to install the panel and how to configure it to work with associated devices such as keypads and sirens. Topics include
how to mount the panel on a flat surface, how to wire the panel, and how to enroll and placement test wireless devices.
2.1 Hardware Installation
The following procedure describes how to mount th ePC9155 alarm panel on a flat surface.
1. Select a suitable location for the alarm panel. The location should have low RF interference (See “
2.4 Wireless Device Placement Test
” on
page 5), and be in a dry area, close to an unswitched AC outlet, phone line (if required), and Ethernet cable (if required). DO NOT mount the
panel on an electrical box. Position the panel away from metal objects (e.g., appliances, furnace, duct work, etc.).
2. Gently pry the front cover from the chassis using a small slotted screwdriver in the slots provided.
3. If the battery is covered with a protective plastic bag, remove the battery from the panel and discard the bag. To remove the battery, depress
the plastic retainer on the right side of it then lift the battery from the housing.
4. If required, connect the battery cable to the battery connector on the PC board.
5. Remove the terminal protection from the battery.
6. Install the battery cable on the battery spade lug terminals [(+)Red, (-)Black)]. To install, slide the left side of the battery [(+) terminal] under
the left battery retaining bracket.
7. Insert a slot screwdriver between the battery and right retaining bracket. Lever the right retaining bracket to the right while pressing the bat-
tery firmly in place.
8. Route wiring through the channels provided to the wiring access hole. See Figure 2-3.
9. Secure the unit to the wall using the mounting holes provided.
Figure 2-2 GPRS/Ethernet Module Wiring Details
i
For PC9155 models equipped with an internal transformer, route AC wiring through the AC wiring guide
then through the access hole adjacent to the internal transformer. Secure the AC line and neutral (N) wir-
ing to the fused side of the terminal block as indicated.
For PC9155D models, route the RJ-45 terminated CAT5 Ethernet cable through the wiring guide then
through the wiring access hole and connect to the RJ-45 jack located on the TL265GS module.
Ethernet communication lines must be connected to an approved (acceptable to local authorities)
type NID (Network Interface Device) before leaving the premises (e.g., UL Installations, UL60950
listed NID).
If required, remove/replace the existing coaxial cable and connect theTL265/ TL265GS/GS2065 to
an external antenna.
Figure 2-1 AC Fuse Block
FUSE)XVH
'*
)XVH
250V
AC/
160mA
7R,QWHUQDO7UDQVIRUPHU
$&,QSXW
/LQH
1HXWUDO
1
3&%
$17(11(
6,0&DUG
7RDOWHUQDWHH[WHUQDO
DQWHQQDFRQQHFWLRQ
5('
3&
3&/,1.
1(7:25.
7 5 7,3 5,1* ,2 ,2$8;$8;$& $&
%$77(5<&211(&7,211276+2:1
*1'6+/'
To Router/Ethernet
Jumpering Ethernet cable to ground
may cause communication problems.
Use with caution.
GS2065/
TL265/TL265GS
,QVHUWVPDOOIODWKHDGVFUHZGULYHU
EHWZHHQFDEOHDQG5[7[PRGXOH
WKHQJHQWO\SU\SOXJORRVH
To remove connector:
NOTE: Removal with fingers may
damage connector.
Vista de pagina 7