5 Installer Programming
5-10
[350] Communicator Format Options
1st Telephone Number 2nd Telephone Number 3rd Telephone Number 4th Telephone Number
CP
01 20 BPS, 1400 Hz 02 20 BPS, 2300 Hz 03 DTMF Contact ID 04 SIA FSK
05 Future Use * 06 Residential Dial
* Failure to communicate using Residential Dial will not generate a FTC trouble.
Refer to Appendix B for additional details.
Opt 1 Opt 2 Opt 3 Opt 4 Opt 5-8
Opt 1 Opt 2 Opt 3 Opt 4 Opt 5-8
1st Telephone 2nd Telephone 3rd Telephone 4th Telephone
Opt 1 Opt 2 Opt 3 Opt 4 Opt 5-8
1st Telephone 2nd Telephone 3rd Telephone 4th Telephone
Opt 1 Opt 2 Opt 3 Opt 4 Opt 5-8
1st Telephone 2nd Telephone 3rd Telephone 4th Telephone
Opt 1 Opt 2 Opt 3 Opt 4 Opt 5-8
1st Telephone 2nd Telephone 3rd Telephone 4th Telephone
Communications Cancel Window 005-255 Minutes (CP-01 Only)
000 005 000
Wireless Device Low Battery Transmission Delay 000-255 Days, 000 = No Delay
030 030 030
Delinquency Transmission Delay 000-255 Hrs/Days, 000=Disabled
007 007 007
Test Transmission Cycle (Land-Line) 000-255 Hrs/Days, 000=Disabled
060 060 060
For Future Use
030 030 030
AC Failure Communication Delay 000-255 Mins/Hrs, 000 = No Delay
010 010 010
TLM Trouble Delay 000-255 x 3 Seconds, 000 = No Delay
030 030 030
Swinger Shutdown (Maint & Rest) 000-014, 000=Disabled
000 030 000
Communication Delay 000-255 Seconds, 000 = No Delay
003 003 003
Swinger Shutdown (Alarms & Rest) 000-014, 000=Disabled
003 003 003
Swinger Shutdown (Tampers & Rest) 000-014, 000=Disabled
Def
[377] Communication Variables
NA
003
CP
001
EU
003
Def
Def
Def
9
Def
Def
[376] System Test Transmissions Communicator Call Directions
For Future Use
Def
Def
[375] System Maintenance Alarm/Restore Communicator Call Directions
For Future Use
Def
9

Def
Def
Def
Def
Def
Def
Def
[367] Opening/Closing Communicator Call Directions
For Future Use
Def
Def
[359] Tamper Alarm/Restore Communicator Call Directions
For Future Use
Def
9

Def
Def
Def
Def
Def
9
Def
[351] Alarm/Restore Communicator Call Directions
1st Telephone 2nd Telephone 3rd Telephone 4th Telephone For Future Use
NA
04 04
EU
04
NA
04
CP
04
EU
04
NA
04
CP
04
EU
04
NA
04
CP
04
EU
04
Periodic Test Transmission
System Test
Walk Test Begin
For Future Use
[348] Test Transmission Reporting Codes
Walk Test End
Vista de pagina 28
1 2 ... 24 25 26 27 28 29 30 31 32 33 34 ... 79 80