5.3 Programming Descriptions
5-22
5.3 Programming Descriptions
This section describes all of the PC9155 programming options.
[001]-[002] Zone Definitions
Each of these sections requires a 2-digit entry to determine how a zone functions. Refer to sections [132] to [134] for zone attribute programming.
Zone Types
i
Fire zones and 24-Hour zones go into alarm whether the system is armed or disarmed and do not follow the exit delay.
00
Null Zone: This zone type is intended for zones that are NOT used.
01
Delay 1: This zone type follows the Entry Delay 1 and Exit Delay timers programmed in section [005] and is normally used for entry/exit doors. The
exit delay starts as soon as the panel is armed. The zone may be opened and closed during the delay time without causing an alarm. After the exit delay
time has expired, opening the zone starts the entry delay timer. During the entry delay time, the keypad buzzer sounds steadily to advise the user that
the system should be disarmed. If the panel is disarmed before the entry delay expires, no alarm is generated.
02
Delay 2: This zone type operates the same as the Delay 1 [01] zone except it follows the Entry Delay 2 time which is set in section [005].
03
Instant: This zone type is normally used for door/window contacts, but is instant when opened after the exit delay expires.
04
Interior: This zone type is used with interior motion detectors. Interior zones have an exit delay and an entry delay if a delay type zone has been vio-
lated first. The zone goes into alarm when the entry delay of the delay type zone has expired, if the system has not been disarmed. If the protected area
is entered without entering the delayed entrance and an interior zone is violated, an immediate alarm is generated.
05
Interior Stay/Away: If the system is Stay armed, this zone type is bypassed. If the system is Away armed, the zone acts like an interior type zone [04].
06
Delay Stay/Away: If the system is Stay armed, this zone type is bypassed. If the system is Away armed, this zone will always follow the entry delay
time for Entry Delay 1 when violated.
i
The automatic bypass on Stay/Away type zones is NOT removed by any event other than a valid exit through a delay type 1 zone during the exit delay,
arming using the Away function key or by pressing [
][1] while armed.
07-08
For Future Use
09
24 Hour Supervisory (Hardwired): The zone is similar to a fire zone. Supervision options (NC, EOL, and DEOL) do not affect the functionality of
the zone. The Restored state of this zone type is 5.6 K zone end-of-line, the Alarm state is short and the Trouble state is open.
i
This zone type must not be used for wireless zones.
10
24 Hour Supervisory Buzzer: When violated, the system buzzer will sound steadily at medium volume until a valid access code is entered.
11
24 Hour Burglary: This zone type is active at all times. It reports an alarm if the panel is armed or disarmed. This zone type sounds the bell for the
length of Bell cut-off (section [005]) if the audible attribute is enabled.
12
For Future Use
13
24 Hour Gas: Similar to 24 Hour Burglary except for System Event output type and SIA identifier.
14
24 Hour Heat: Similar to 24 Hour Burglary except for System Event output type and SIA identifier.
15
24 Hour Medical: Similar to 24 Hour Burglary except for System Event output type and SIA identifier.
16
24 Hour Panic: Similar to 24 Hour Burglary except for System Event output type and SIA identifier.
17
24 Hour Emergency: Similar to 24 Hour Burglary except for System Event output type and SIA identifier.
18
For Future Use
19
24 Hour Water: Similar to 24 Hour Burglary except for System Event output type and SIA identifier.
20
24 Hour Freeze: Similar to 24 Hour Burglary except for System Event output type and SIA identifier.
21
For Future Use
22
Momentary Keyswitch Arm. A keyswitch device may be connected to the zone programmed as momentary keyswitch arm. Momentary activation of
the zone alternately arms/disarms the system and silences alarms. Tampers and faults will only initiate their respective trouble sequence. The keypad
will not display an indication when this type of zone is activated.
i
With audible alarm active, using the keyswitch when disarmed is the same as entering an access code at the keypad. Using the keyswitch during the
first 30 seconds of a delayed fire alarm is the same as pressing a key at the keypad (the 90 second delay will start).
The violation of a keyswitch zone arms or disarms the system. Violation of this zone type will NOT be logged or transmit the Police code.
A bypass on this zone type will not be un-bypassed when the system is disarmed. When the zone is bypassed, a zone bypass event buffer log and com-
munication occurs immediately, NOT when the system is armed.
23
Maintained Keyswitch Arm (Hardwired): Keyswitch devices can be connected to zones programmed as Maintained Keyswitch arm. In the restored
state, the panel is disarmed. The violation of the zone arms the panel. Tampers and faults begin their associated trouble sequence. If the system is
armed with this keyswitch, and then disarmed by another method, then the keyswitch zone must be restored and then violated before the system can be
armed with this zone again. The same is true for disarming, if the zone is restored and the system armed, the keyswitch zone must be violated and then
restored to disarm the system.