5.3 Programming Descriptions
5-28
[018] Sixth System Options
[023] Tenth System Options Code
[024] Eleventh System Options Code
Option Description
[1]
For Future use
[2]
ON: Keypad Tamper Enabled. All system keypads will generate tamper troubles and restorals.
OFF: Keypad Tampers are disabled. System keypads will NOT generate tamper troubles and restorals.
[3]-[4]
For Future use
[5]
ON: Keypad Buzzer Follows Bell Enabled. The keypad buzzers follow the bell status.
OFF: Keypad Buzzer Follows Bell Disabled. The keypad buzzers do NOT follow all bell activity. Only designated alarms will activate the keypad
buzzer.
i
DSC recommends the use of a transformer with the system keypad if this feature is enabled.
[6]-[8]
For Future Use
Option Description
[1]
On: Chime on Openings Enabled. When a zone with the door chime attribute ON is violated, the system keypads and sirens (if enabled) sound door
chime beeps.
Off: Chime on Openings Disabled. When a zone with the door chime attribute ON is violated, the system keypads and sirens (if enabled) do not
sound door chime beeps.
[2]
On: Chime on Closings Enabled. When a zone with the door chime attribute ON is restored, the system keypads and sirens (if enabled) sound door
chime beeps.
Off: Chime on Closings Disabled. When a zone with the door chime attribute ON is restored, the system keypads and sirens (if enabled) do not
sound door chime beeps.
[3]
ON: Test Transmission while Armed Only. The Periodic Test Transmission reporting code is transmitted when the system is armed, depending on
which test transmission options are enabled.
OFF: Test Transmission while Armed and Disarmed. The Periodic Test Transmission reporting code is transmitted when the programmed time
occurs regardless of the armed state of the panel.
i
This feature is intended to operate with the test transmission counter set to hours.
[4]
ON: Test Transmission Counter in Hours: Sets the test transmission counter to hours.
OFF: Test Transmission Counter in Days: Sets the test transmission counter to days.
[5]
ON: Switching from Away to Stay Disabled. The user can not switch from Away mode (highest armed mode) to Stay mode (lower armed mode)
with the arming function keys or the [
][1] feature.
OFF: Toggling between Away and Stay is permitted.
[6]
For Future Use
[7]
ON: Trouble Beeps are Silent. Trouble beeps will NOT sound a double beep every 10 seconds unless the trouble is caused by a fire trouble.
OFF: Trouble beeps will sound every 10 seconds: Trouble beeps will sound a double beep every 10 seconds for all troubles.
[8]
ON: Keyswitch Arms in Away Mode. Keyswitch zones on the system arm the system in Away mode.
OFF: Keyswitch Arms in Stay or Away. When a keyswitch zone is used to arm the system, the final armed mode depends on whether the user vio-
lates a delay zone during exit delay. If the user violates a delay zone, the system will arm in Away mode. If not, the system will arm in Stay mode.
(This is similar to arming the system at the keypad with an access code. The exit delay will be audible.)
Option Description
[1]
ON: Temperature Display Enabled. The keypad displays the temperature received from the lowest numbered external siren. If the local clock dis-
play is also enabled, then the keypad displays date, time, and temperature.
OFF: Temperature Display Disabled. The keypad will NOT display the temperature.
[2]
ON: Temperature displayed in degrees Celsius. The keypad displays the temperature in Celsius.
OFF: Temperature displayed In Fahrenheit. The keypad displays the temperature in degrees Fahrenheit.
[3]
ON: PC9155 Internal Siren Enabled. The internal siren on the panel is enabled.
OFF: PC9155 Internal Siren Disabled. The internal siren on the panel is disabled.
[4]
ON: Inactivity is Monitored by all Zones. If no violations occur on any burglary zones during the Inactivity Timer windows (section [591]-[592]),
the panel communicates the Fail to Report In code, if programmed.
i
This code is not transmitted for panels that are Away armed.
Troubles and bypassed zones will not cause activity indications.
OFF: Inactivity is Monitored only by 24-hour Non-alarm Zones. If no violations occur on a 24-hour non-alarm zone during the Inactivity Timer
windows (section [591]-[592]), the panel communicates the Fail to Report In code, if programmed.
[5]-[8]