5.3 Programming Descriptions
5-42
[804][141]-[156] Wireless Key Function Key Options
Up to 6 unique functions can be programmed for each wireless key. Each section requires four 2-digit entries. The following table describes each programmable function.
[804][181]-[182] Wireless Key Enable/Disable
These sections enable each individual key enrolled on the system. The keys are all enabled on the system by default.
[804][201]-[204] Wireless Keypad Serial Number
These sections are used to enter the wireless keypad serial numbers. The number is an 8-digit hexadecimal entry. To toggle between decimal and hexadecimal value
entries, press [
].
[804][301]-[304] Wireless Siren Serial Number
These sections are used to enter the wireless siren serial numbers. The number is an 8-digit hexadecimal entry. To toggle between decimal and hexadecimal value
entries, press [
].
[804][311]-[314] Wireless Siren Options for Sirens 1-4
Entry Description DSC Wireless Key
00
Null Key (Key Not Used) YES
03
Stay Arm YES
04
Away Ar m YE S
05
[][9] No-Entry Arm [][9] No-Entry Arm can be used if the wireless key being used is identified.
06
[][4] Chime On / Off YES
13
Command Output 1 [][7][1] [][7][1] commands can be used with an access code if the wireless keys are identified.
14
Command Output 2 [][7][2] [][7][2] commands can be used with an access code if the wireless keys are identified.
16
[][0] Quick Exit YES
17
[][1] Reactivate Stay/Away Zones YES
25
Instant Stay Arm YES
27
Disarm (Off) Disarming can be used with an access code, as long as the wireless keys are identified.
29
Auxiliary Alarm YES
30
Panic Alarm YES
33
Night Arm YES
Each section contains the following 8 options:
Option Description
[1]
ON: Siren Enabled. The WT49X1 shall activate at full volume for fire, burglary, and CO alarm conditions. This option shall also enable walk test
and system test indications for WT49X1 modules, and placement test, walk test, and system test indications for WT4911 modules.
OFF: Siren Disabled. The WT49X1 will not activate for fire, burglary, CO Alarm, walk test or system test indications. Placement test will still be
sounded by WT4901 modules.
[2]
ON: Buzzer Notifications Enabled. The siren will activate audible signals for entry/exit delays, and 24 hour buzzer zone alarms. This may be desir-
able for indoor sirens, but not outdoor sirens.
OFF: Buzzer Notifications Disabled. Audible signals will not be sent.
[3]
ON: Door Chime Enabled. The siren will activate for door chime conditions.
OFF: Door Chime Disabled. The siren will not be activated for door chime conditions.
[4]
ON: Trouble Beeps Enabled. The siren will activate for trouble beep conditions. Trouble beeps are sounded until any key on the keypad is pressed or
until all trouble conditions are restored. This is intended for indoor sirens, but not outdoor sirens or sirens that are mounted in a sleeping area.
Off: Trouble Beeps Disabled. The siren will not activate for trouble beeps.
[5]
ON: Bell Squawks Enabled. The siren will activate programmed bell squawk conditions (e.g., arming, disarming, disarming with alarms in mem-
ory). This may be desirable for outdoor sirens, but not indoor sirens. These squawks are sounded at full alarm volume.
OFF: Bell Squawks Disabled. The siren will not activate for bell squawk conditions.
[6]
ON: Strobe Enabled. The strobe will activate for alarms, placement test, walk test, system test and arm/disarm squawk indications. The strobe can be
used to identify a system alarm before entering the premises.
OFF: Strobe Disabled. The strobe will not be activated.
[7]
ON: Buzzer Alarm / Strobe Follows Bell Time Out. Indoor Siren - If the indoor siren is set for buzzer notifications (option 2), buzzer alarms, such
as 24 Hr buzzer zone types are shut off after they have been active for the duration of BTO. Outdoor siren: If the strobe is enabled on the outdoor siren
(option 6), the strobe will shut off once the siren is shut off at the end of the bell duration.
OFF: Buzzer Alarms / Strobe Follows Alarm Condition. Indoor siren - The siren will sound the buzzer alarm until the alarm condition has been
acknowledged (silenced) at the keypad. Outdoor siren: The strobe will continue until an access code has been entered at a system keypad, or a suc-
cessful disarming request has been serviced.
[8]
ON: Siren Tamper Enabled. Tamper conditions from the siren will generate a tamper trouble. The panel will log and communicate the event.
OFF: Siren Tamper Disabled. Tamper conditions from the siren will not generate a tamper trouble. The panel will log and communicate the event.
If a siren tamper condition is present in [
][2], turning off this option shall clear the trouble from the system.
i
This option must be Off for CP-01 compliance.