2 Installation
2-6
To perform a global placement test on a zone, type [00]. In this mode, all wireless zones, keypads and sirens are placement tested at the same
time. To perform another individual placement test on a zone, exit the global placement test by pressing [#] and begin a new placement test.
3. Place the wireless device(s) in the intended mounting location(s).
4. Activate the device(s) as described in the associated installation sheet.
If the alarm system receives a STRONG signal, the bell sounds once and “Location is Good” is displayed on the LCD.
If the alarm system receives a WEAK signal, the bell sounds 3 times and “Location is Bad” is displayed on the LCD.
If the alarm system indicates no response, reposition the wireless device(s) and repeat the test.
For individual placement tests, repeat step 2-3 for each device.
5. When placement testing is complete, press [#] to exit Installer Programming.
2.5 Individual Wireless Device Placement Test for Sirens and Keypads
Individual placement testing can be performed on wireless sirens and keypads. Use the scroll keys or enter a 2-digit entry to select a specific key-
pad or siren, depending on which placement test section is entered.
Wireless Device Placement
1. To individually test keypads or sirens, press:
[ ][8][XXXX][905] - for wireless keypads
[
][8][XXXX][906] - for wireless sirens
NOTE: [XXXX] represents the installer code (default 5555).
2. Type 1 to 4 for keypad/siren 1-4 or scroll to the desired device and press [ ] to begin the individual placement test.
3. Place the wireless device in the intended mounting location.
4. Activate the device as described in the associated installation sheet.
If the alarm system receives a STRONG signal the bell sounds once and “Location is Good” is displayed on the LCD.
If the alarm system receives a WEAK signal the bell sounds 3 times and “Location is Bad” is displayed on the LCD.
If the alarm system indicates no response, reposition the wireless device and repeat the test.
5. Repeat Step 2-3 for each device. Once the placement test is complete for the device, press [#] once to select the next similar device.
6. When placement testing is complete, press [#][#][#] to exit Installer Programming.
2.6 GPRS/Ethernet Module Setup/Initialization
After system installation and programming, ensure that the following sections are programmed:
Central Station Phone Number, (Template Programming - Entry 5) (if applicable, in sections [301]-[303] & [305])
Account code, section [310], (Template Programming - Entry 6)
Communications Format, Section [350]- set to [03] Contact ID or [04] SIA FSK
GPRS/Ethernet Module Enable section [382] Option[5] - set to GPRS/Ethernet Module Enabled
i
Two-way wireless keys must be activated by pressing any key before they become functional.
To placement test a wireless keypad, press number keys 0-9.
To placement test a wireless siren, press the Test button or tamper the device.