PC9155 Wireless Alarm System
5-4
NA CP EU
ON OFF
1
999
[F] Key Enabled [F] Key Disabled
2
[P] Key Audible (Siren / Beeps) [P] Key Silent
3
999
Quick Exit Enabled Quick Exit Disabled
4
999
Quick Arming Enabled (*0 And Function Keys) Quick Arming Disabled (Funct. Keys Req. Code)
5
Code Required For Bypassing No Code Required
6
Master Code Not Changeable Master Code Changeable
7
999
TLM Enabled TLM Disabled
8
System Tamper Enabled System Tamper Disable
NA CP EU
ON OFF
1
Cross Zoning is Enabled Police Code is Enabled
2
9
Exit Delay Restart Enabled Exit Delay Restart Disabled
3
Blank Keypad When Not Used Keypad Active Always
4
Code Required To Remove Keypad Blanking No Code Required
5
999
Keypad Backlighting is Enabled Keypad Backlighting is Disabled
6
999
ID WKEY Not Required For Disarming ID WKEY Required For Disarming
7
Bypass Status Displayed While Armed Bypass Status Not Displayed While Armed
8
Daylight Savings Time Enabled Daylight Savings Time Disabled
NA CP EU
ON OFF
1
For Future Use
2
Keypad Tampers Enabled Keypad Tampers Disabled
3
For Future Use
4
For Future Use
5
Keypad Buzzer Follows Siren Enabled Keypad Buzzer Follows Siren Disabled
6
For Future Use
7
For Future Use
8
For Future Use
NA CP EU
ON OFF
1
For Future Use
2
For Future Use
3
Test Transmission While Armed Only Test Transmission While Armed/Disarmed
4
Test Transmission Counter In Hours Test Transmission Counter In Days
5
Switching From Away To Stay Disabled
A
way To Stay Toggle Option Permitted
*
6
For Future Use
7
Trouble Beeps Are Silent Trouble Beeps Will Sound Every 10 Seconds
8
Keyswitch Arms In Away Mode Only Keyswitch Arms In Stay Or Away
NA CP EU
ON OFF
1
999
Temperature Display Enabled Temperature Display Disabled
2
99
Temperature Displayed in Celsius Temperature Displayed In Fahrenheit
3
999
PC9155 Internal Siren Enabled PC9155 Internal Siren Disabled
4
999
Inactivity monitored by all zones Inactivity monitored only by 24 Hr Non-alarm zones
5
For Future Use
* 6
For Future Use
7
For Future Use
8
For Future Use
NA CP EU
ON OFF
1
Zone 33 is Fast Loop Response Zone 33 is Normal Loop Response
2
Zone 34 is Fast Loop Response Zone 34 is Normal Loop Response
Opt
[015] Third System Options
Opt
[023] Tenth System Options
Opt
[024] Eleventh System Options
Opt
[016] Fourth System Options
Opt
Opt
[018] Sixth System Options
[030] Zone Loop Response Options