PC9155 Wireless Alarm System
2-2
Figure 2-3 Mounting & Wiring Details
Phone Line T1-Brn Connects to in-house phone line
R1- Gra Connects to in-house phone line
Tip - Grn Connects to outside phone Line. Allows system to seize
the phone line from devices connected to T1-R1
Ring - Red Connects to outside phone Line. Allows system to seize the phone line from devices connected to T1-R1
I/O I/O - 1 Can be configured as a PGM output (50mA) or hard wired zone input (Zone 33)
I/O - 2 Can be configured as a PGM output (50mA) or hard wired zone input (Zone 34)
Aux Aux - Provides common connection for hard-wired zones and Aux+ power
Aux + Provides +12V
DC, 200mA (Max.) for PGMs and modules
AC ~ Connects directly to external 16.5V
AC transformer or fused internal transformer
~ Connects directly to external 16.5V
AC transformer or fused internal transformer
FUSEFUSE
DG009034
%$&.9,(:
)52179,(:&29(55(029('
T- 1
R-1
TIP
RING I/O2 I/O1
- AUX +
AC AC
7RLQWHUQDO
WUDQVIRUPHU
LIHTXLSSHG
7R$&
PDLQV
3KRQH
/LQH,1287
,2
:LULQH
(WKHUQHW
&RQQHFWLRQ
5('
3&/,1.3&/,1.
Internal
Transformer
Version Only
Internal
Transformer
Version Only
AC
CAUTION: The Ethernet communication lines must be connected first to an Approved (acceptable to the local authorities) type
NID (Network Interface Device) before leaving the premises (e.g., UL installations, UL60950 Listed NID).
T-1 R-1 Tip Ring
I/OTelephone
21
Aux AC
PC9155
Comentarios a estos manuales