
[*][7] – Command Outputs:
Summary:
This command provides the ability to activate/deactivate PGM outputs programmed as a ‘Command
Output’ option.
Operation:
[*][7] + [1] or [*][7] + [1] + [Access Code]
[*][7] + [2] or [*][7] + [2] + [Access Code]
[*][9] – No-Entry Arming:
Summary:
If armed using this method, all ‘Delay’ type zone will become instant (no entry delay) and all ‘Stay/Away’
type zone will be automatically bypassed
Operation:
[*][9] + [Access Code]
Note:
- [*][1] may be used after arming in this mode if ‘Stay/Away’ zones are to be active
[*][8] – Installer Programming:
Summary:
This command allows the user to enter ‘Installer Programming’.
Operation:
[*][8] + [Installer Code]
Notes:
- The default installer code is ‘5555’.
- The system must be disarmed before entering installer programming
- Attempting to enter installer programming while armed, the keypad will emit a long steady tone for 3-
seconds after [*]8] is entered and the LCD keypad message ‘Function Not Available’ will also be displayed
Comentarios a estos manuales