Step 5 – Test all wireless devices and detectors
Step 1 – Enter Wireless Placement Test ([*][8] + Installer Code + [904])
- the display will read ‘Activate Device For Test’
Step 2 – Activate each wireless device/detector one at a time from the proposed mounting location
Wireless Keypad [*] and [1] simultaneously
Wireless sirens (WT4901, WT4911) – activate tamper
Door/window contact – activate tamper or violate contact
Motion detectors – activate tamper
Smoke Detector – activate tamper
Glassbreak Detector – activate tamper
Panic Pendant – Press and hold button for 2-3 seconds
CO Detector – activate tamper
Flood Sensor – activate tamper
Step 3 – The test result will be indicated:
Good Result Bad Result
Keypad Display ‘Location is Good’ ‘Location is Bad’
Siren* 1 Squawk 3 Squawks
* PC9155 and WT4901
Note:
- the above placement test is when enabled for the ‘Global Placement Test’. If ‘’Individual Placement Test’,
a different section number exits for each type of device:
Vista de pagina 36