Vista de pagina 45
[*][6] – User Functions:
[*][6] + [Master Code or Supervisory Code] + [Option]
Option [1] – Program Time/Date
Step 1 – [*][6]+ [Master Code or Supervisory Code]
Step 2 – Press [1]
Step 3 – [HH:MM MM:DD:YY]
The control panel Time/Date needs to be programmed each time AC and backup battery are
removed.
Additional Information – when AC and backup battery are removed, the control panel will log a
‘Cold Start’ to the event buffered when power is restored
Option [4] – System Test
Step 1 – [*][6]+ [Master Code or Supervisory Code]
Step 2 – Press [4]
When initiated, the control panel will test the following:
- Keypad (LED indicators, LCD screen, buzzer)
- Bell output (PC9155 siren and WT4901/WT4911)
-Battery
- Central station communications (reports a ‘System Test’ reporting code)
Option [5] – User Enabled DLS Window
Step 1 – [*][6]+ [Master Code or Supervisory Code]
Step 2 – Press [5]
When initiated, the control panel will answer an incoming DLS call (Double Call) for the next 6
hours*
* may be programmed to answer for 1 hour when initiated, Section [702], Toggle#7
Option [6] – User Initiated Call-up
Step 1 – [*][6]+ [Master Code or Supervisory Code]
Step 2 – Press [6]
When initiated, the control panel will call the DLS computer
Option [8] – User Walk Test Mode
Step 1 – [*][6]+ [Master Code or Supervisory Code]
Step 2 – Press [8]